| Electrical Specs | Single phase, 115v/60/1, 6.5 ft cord with NEMA 5-15 plug, Amperage: 6.4, Max Fuse/HACR Breaker: 15 A |
| Operating Limits | Ambient Temp Range: 45 – 100°F, Water Temp Range: 45 – 90°F, Water Pressure: 10 – 113psig, Voltage Range: 104 – 127V, Heat Rejection: 2900 BTU/hr, Refrigerant Charge: R-134a, (10.6 oz. / 300 |
| Plumbing Specs | 1/2″ FPT Inlet, Minimum 3/8″ Nominal ID Copper Water Tubing or Equivalent, 1/2″ FPT Outlet, Minimum 1/4″ Nominal ID Hard Pipe or Equivalent, Minimum 1/4″ Nominal ID Copper Water Tubing or Equ |
| Shipping Weight | 163 |
| Utility Consumption | 6.23 kWh per 100 lbs @ 90/70, 23.9 gal of Potable Water per 100 lbs @ 90/70 |
| Width | 23.75 in. |
| Depth | 28 in. |
| Height | 39 in. |
| Parts | 3 Years |
| Labor | 3 Years |
| Parts (Compressor) | 5 Years |